Heating cable - heating wire for water installations and gutters. This heating cable with a thermostat is an intelligent solution for protecting pipes from freezing. It automatically turns on when the temperature drops to 6°C and turns off when it reaches 13°C. It is easy to install and requires no maintenance after being connected to the 230V network. Thanks to its waterproofness, UV resistance, and flexibility of the material, it works great in various conditions, protecting pipes, gutters, and other elements from low temperatures.
Product compliance details: Manufacturer and person responsible for the product
Responsibility for the Product
Manufacturer DMR Group Poland ul. Woźniaka 42 40-389 Katowice Poland [email protected]
Responsible person DMR Group Poland Woźniaka 42 40-389 Katowice Poland [email protected]
Description
It is ideally suited for use in homes, outdoors, and industrial facilities, offering a versatile solution for protection against the effects of freezing temperatures.
Where to use?
- Any water installation, including pipes or valves, sanitary and sewage systems - regardless of whether they are made of plastic, copper, or steel.
- Air conditioners, heat pumps, drain pipes, or drip trays.
- Vegetation, trees, crops, greenhouses
- Gutters, valves, meters
- Freezing components of mechanisms in automatic gates
- Water drainage
How does the thermostat work?
Our innovative heating cable is equipped with a smart thermostat that activates heating at a pipe temperature of 6°C and turns off when the temperature reaches 13°C. This will completely and under all conditions protect pipes and other installations from freezing.
How to install?
1. Lay out the cable, avoiding connecting it while coiled.
2. If the cable is very stiff at low temperatures, connect it temporarily to power to increase flexibility.
3. Proceed with the installation of the cable.
4. Ensure that the installation site is easily accessible and free from obstacles.
5. Secure the thermostat to the coldest part of the pipe using insulating tape, ensuring good contact with its black part, resembling a black button.
6. Lay the cable along the pipe, securing it with tape every 30-60 cm.
7. Insulate the pipe and cable using appropriate insulating materials.
Heating efficiency with pipe insulation (i.e., critical temperature)
- 15mm diameter pipe down to -45°C
- 22mm diameter pipe down to -45°C
- 28mm diameter pipe down to -40°C
- 35mm diameter pipe down to -40°C
- 42mm diameter pipe down to -35°C
- 48mm diameter pipe down to -30°C
- 60mm diameter pipe down to -25°C
- 76mm diameter pipe down to -20°C
Heating efficiency without insulation (i.e., critical temperature)
- 15mm diameter pipe down to -20°C
- 22mm diameter pipe down to -13°C
- 28mm diameter pipe down to -10°C
- 35mm diameter pipe down to -7°C
- 42mm diameter pipe down to -5°C
- 48mm diameter pipe down to -4°C
- 60mm diameter pipe down to -3°C
- 76mm diameter pipe down to -2°C
Technical data:
- power consumption: 64W
- length of heating part: 400cm
- total length: 580cm (including 400cm heating part + supply part)
- waterproof rating: IP68
- maximum temperature achieved by the cable: 65°C